← Solutions

Liquid waste haulers

Tested in pilot

Treat liquid waste close to the point of collection

Haulers already control the waste. An HTR skid near the collection points allows it to be treated in-house, capturing the margin that goes to third-party disposal sites today.

The problem

Hauling is where the cost is

Collected liquid waste usually travels long distances to third-party disposal: incinerators, treatment plants or injection wells. The hauler pays the tipping fee, the trucking and the waiting time, and depends on disposal capacity outside its control.

The solution

Treatment at the yard

  • A modular HTR skid installed at or near the collection yard
  • Handles mixed loads: solvents, oily water, chemical residues, off-spec fuels
  • Halogens captured on the skid, so chlorinated loads can be accepted
  • Syngas runs a gas engine for on-site power, or is used as fuel gas

Mixed loads

No catalyst means variable, contaminated loads do not damage the reactor.

50,000 gpd per skid

Each skid treats up to 50,000 gallons of liquid waste a day, wastewater and hydrocarbons combined. Skids can be added as volumes grow.

Two revenue streams

The treatment fee is retained, and power or product from the syngas is added.

Contaminants

Where the contaminants go

Collected liquid waste containing halides, sulfur and organic nitrogen, treated at the yard and converted to power.

Halides (Cl, Br, F)

Converted to HCl, HBr and HF in the reactor and captured on the sorbent quench inside the skid.

Sulfur

Leaves the reactor mainly as H₂S with some COS. COS is hydrolyzed and H₂S removed in a conventional sulfur step sized to the feed.

Organic nitrogen

Mostly ends up as N₂. The small share of NH₃ and HCN is picked up in the condensate and treated in a sour water stripper.

Pilot program

The pilot ran an industrial solvent blend and mixed chemical waste. Data is available under NDA.

Suitability

Haulers with steady volumes of organic liquid waste, a yard or site with power demand or a grid connection, and a per-barrel disposal cost today.

Every case is unique

Every stream is different.

Share a description of the waste stream and RegenSyn Energy will give a first view of whether it fits the HTR and what it could produce. An NDA can be put in place first.

A feasibility study or pilot test is available on request.