
PFAS-laden waste streams
Tested in pilot
Break down PFAS instead of storing it
Foam fractionation, reverse osmosis and ion exchange all produce a concentrate that still has to go somewhere. The HTR breaks it down, and dilute streams can also be fed directly.
The problem
Separation leaves a concentrate
Removing PFAS from water moves it into a smaller, stronger stream. Today that concentrate is often stored or injected underground, and both options are under growing regulatory scrutiny.1
The solution
Break the carbon-fluorine bond
- The PFAS-laden water is injected as the reactor’s water feed, directly into the high-temperature zone
- At 2,100 to 3,600 °F with controlled residence time, the carbon-fluorine bonds are broken
- Fluorine leaves as hydrogen fluoride and is captured on the skid’s sorbent quench as solid fluoride
- The carbon from the PFAS ends up as syngas, like any other organic in the feed
High temperature
Operating range well above the temperatures needed to break carbon-fluorine bonds.
Fluorine captured
HF is caught inside the skid, not passed to a downstream scrubber.
With or without separation
Works alongside an existing concentration step, or on dilute streams fed directly.
The chemistry
Why temperature matters for PFAS
The carbon-fluorine bond is one of the strongest bonds in organic chemistry.2 Breaking it reliably takes high temperature held for long enough, and then a safe destination for the fluorine.
Heat
The HTR torch zone runs at 2,100 to 3,600 °F (1,150 to 2,000 °C), above typical thermal treatment conditions.
Time
Residence time at temperature is a design variable, set for the most refractory compounds in the feed.
A destination for the fluorine
Fluorine is converted to HF and captured on the sorbent quench before the gas leaves the skid.
1. US EPA, Interim Guidance on the Destruction and Disposal of PFAS and Materials Containing PFAS, April 2026 update.
2. O’Hagan, D., Chem. Soc. Rev. 2008, 37, 308-319, doi:10.1039/b711844a.
Contaminants
Where the contaminants go
PFAS breakdown: separation concentrates the PFAS and the HTR skid decomposes the concentrate. Dilute streams can also be fed directly.
Concentrate as the water feed
The PFAS concentrate goes into the reactor as its water and steam source. A support fuel, natural gas or waste hydrocarbons, supplies the heat.
Fluorine to solid fluoride
Carbon-fluorine bonds are broken in the reactor. The fluorine leaves as HF and is captured on the sorbent quench, ending up as a solid fluoride.
Measured, not assumed
Sampling points after the skid allow testing for residual PFAS and for incomplete byproducts, which is how breakdown performance is verified.

Pilot program
PFAS breakdown was measured in the 2026 pilot, and the fluorine mass balance was closed. Detailed results are available to qualified partners under NDA.
Suitability
Holders of PFAS concentrates: AFFF stocks, foam fractionate, RO reject and regenerant brines. Dilute groundwater can be fed directly or concentrated first.
Every case is unique
Every stream is different.
Share a description of the waste stream and RegenSyn Energy will give a first view of whether it fits the HTR and what it could produce. An NDA can be put in place first.
A feasibility study or pilot test is available on request.