← Solutions

Petrochemical and refining sites

Tested in pilot

Handle problem streams on site

Residues, spent solvents, off-spec product and sour off-gas can be converted on site instead of being shipped out as hazardous waste, adding syngas capacity at the same time.

The problem

Off-site disposal is slow and expensive

Many plants have a few streams that do not fit existing units: too contaminated for a reformer catalyst, too wet or chlorinated for the flare or boiler. They leave site as hazardous waste, with the associated cost, manifests and liability.

The solution

Conversion at the point of generation

  • An HTR skid inside the fence, fed directly from the process, treating up to 50,000 gallons per day of liquids
  • Projects run from 10,000 to 150,000 gallons per day of combined wastewater and waste hydrocarbon, in skids of up to 50,000 gallons per day.
  • The reactor tolerates sulfur, chlorine and salts (no catalyst to poison); sulfur and halogens are handled downstream on the skid, within design limits set per project
  • Halogens captured on the skid; sulfur handled by existing gas treatment where available
  • Syngas routed into the existing syngas header

Minimal pretreatment

Feeds that would poison a catalytic unit need only basic receiving, blending and filtration.

Fits existing utilities

Designed to tie into existing syngas, fuel gas, sulfur recovery and power systems.

Wastewater is the steam

Contaminated process water supplies the steam, so no boiler-feed-water quality is needed.

Business case

Cut disposal cost. Create a syngas product.

Disposal cost avoided

Replaces per-gallon hauling, incineration, blending and injection fees with on-site conversion.

Syngas value created

The syngas can feed hydrogen, methane, methanol or DME production, or power. A stream that was a cost becomes a source of revenue.

Less liability

Organic hazards are decomposed on site instead of being manifested out.

Compared with disposal

Where waste liquids go today, and what remains

RouteWhat happens to the organicsWhat remains
Hazardous-waste incinerationOxidized off site at about 1,800 to 2,200 °F, at a feeAsh and scrubber residue. Highest cost per gallon, limited capacity.
Deep-well injection (Class I)Pumped into deep isolated formations, isolated but not broken downThe waste stays underground. Well capacity and permits are finite.
Fuel blending or cement kilnsBurned as supplemental kiln fuel, energy recoveredOnly high-BTU, low-water, low-halogen loads are accepted.
Biological wastewater treatmentMicrobial oxidation of dissolved organics, partially degradedBiosludge. Toxic or oily loads upset the plant.
Wet air oxidationAqueous oxidation at about 300 to 600 °F and 300 to 2,000 psi, partially oxidizedOrganic acids remain and need biological polishing.
Hydrogen Torch ReformerGas-phase reforming without a catalyst, converted to syngas (H₂ + CO)Syngas product and process condensate. Acid gases removed, halogens captured as solids.

Feed envelope

Streams the HTR can take

Every stream is screened case by case and blended to a site-specific recipe before it enters the reactor. Pilot-tested feeds are marked on the Solutions page.

Hydrocarbons

  • Aromatic solvent and diesel
  • Light petroleum and naphtha
  • Heavy crude and tank bottoms
  • Slop oils with high suspended solids

Oxygenates

  • Oxygenated solvents
  • Glycol and antifreeze
  • Aldehydes and formaldehyde

Aqueous and mixed

  • Dilute aqueous wastewater
  • Oil-water emulsions
  • Sludge with high suspended solids

Nitrogen-bearing

  • Amines from gas treating
  • Nitriles and other N-bearing streams

Halogenated

  • PFAS-bearing streams
  • Chlorinated organics

Not on the list?

Send an SDS or a sample for testing. Streams are screened case by case.

Contaminants

Where the contaminants go

A general process for waste hydrocarbons that carry halides, sulfur and organic nitrogen.

Halides (Cl, Br, F)

Converted to HCl, HBr and HF in the reactor and captured on the sorbent quench inside the skid.

Sulfur

Leaves the reactor mainly as H₂S with some COS. COS is hydrolyzed and H₂S removed in a conventional sulfur step sized to the feed.

Organic nitrogen

Mostly ends up as N₂. The small share of NH₃ and HCN is picked up in the condensate and treated in a sour water stripper.

Pilot program

The 2026 pilot campaign included diesel, mixed chemical waste, an aromatic and oxygenate mix and an industrial heavy aromatic solvent blend. The syngas had no measurable soot, with C₂H₂ below 50 ppm and C₆+ below 170 ppm. Data is available under NDA.

Suitability

Sites with recurring organic waste or off-gas streams that currently go to off-site disposal, and a use for syngas or power.

Every case is unique

Send us your stream.

Share the flow rate, composition and SDS for each waste stream. RegenSyn Energy screens it against the HTR feed envelope and comes back with a screening result and, where useful, a blend proposal. An NDA can be put in place first.

A feasibility study or pilot test is available on request.