
Petrochemical and refining sites
Tested in pilot
Handle problem streams on site
Residues, spent solvents, off-spec product and sour off-gas can be converted on site instead of being shipped out as hazardous waste, adding syngas capacity at the same time.
The problem
Off-site disposal is slow and expensive
Many plants have a few streams that do not fit existing units: too contaminated for a reformer catalyst, too wet or chlorinated for the flare or boiler. They leave site as hazardous waste, with the associated cost, manifests and liability.
The solution
Conversion at the point of generation
- An HTR skid inside the fence, fed directly from the process, treating up to 50,000 gallons per day of liquids
- Projects run from 10,000 to 150,000 gallons per day of combined wastewater and waste hydrocarbon, in skids of up to 50,000 gallons per day.
- The reactor tolerates sulfur, chlorine and salts (no catalyst to poison); sulfur and halogens are handled downstream on the skid, within design limits set per project
- Halogens captured on the skid; sulfur handled by existing gas treatment where available
- Syngas routed into the existing syngas header
Minimal pretreatment
Feeds that would poison a catalytic unit need only basic receiving, blending and filtration.
Fits existing utilities
Designed to tie into existing syngas, fuel gas, sulfur recovery and power systems.
Wastewater is the steam
Contaminated process water supplies the steam, so no boiler-feed-water quality is needed.
Business case
Cut disposal cost. Create a syngas product.
Disposal cost avoided
Replaces per-gallon hauling, incineration, blending and injection fees with on-site conversion.
Syngas value created
The syngas can feed hydrogen, methane, methanol or DME production, or power. A stream that was a cost becomes a source of revenue.
Less liability
Organic hazards are decomposed on site instead of being manifested out.
Compared with disposal
Where waste liquids go today, and what remains
| Route | What happens to the organics | What remains |
|---|---|---|
| Hazardous-waste incineration | Oxidized off site at about 1,800 to 2,200 °F, at a fee | Ash and scrubber residue. Highest cost per gallon, limited capacity. |
| Deep-well injection (Class I) | Pumped into deep isolated formations, isolated but not broken down | The waste stays underground. Well capacity and permits are finite. |
| Fuel blending or cement kilns | Burned as supplemental kiln fuel, energy recovered | Only high-BTU, low-water, low-halogen loads are accepted. |
| Biological wastewater treatment | Microbial oxidation of dissolved organics, partially degraded | Biosludge. Toxic or oily loads upset the plant. |
| Wet air oxidation | Aqueous oxidation at about 300 to 600 °F and 300 to 2,000 psi, partially oxidized | Organic acids remain and need biological polishing. |
| Hydrogen Torch Reformer | Gas-phase reforming without a catalyst, converted to syngas (H₂ + CO) | Syngas product and process condensate. Acid gases removed, halogens captured as solids. |
Feed envelope
Streams the HTR can take
Every stream is screened case by case and blended to a site-specific recipe before it enters the reactor. Pilot-tested feeds are marked on the Solutions page.
Hydrocarbons
- Aromatic solvent and diesel
- Light petroleum and naphtha
- Heavy crude and tank bottoms
- Slop oils with high suspended solids
Oxygenates
- Oxygenated solvents
- Glycol and antifreeze
- Aldehydes and formaldehyde
Aqueous and mixed
- Dilute aqueous wastewater
- Oil-water emulsions
- Sludge with high suspended solids
Nitrogen-bearing
- Amines from gas treating
- Nitriles and other N-bearing streams
Halogenated
- PFAS-bearing streams
- Chlorinated organics
Not on the list?
Send an SDS or a sample for testing. Streams are screened case by case.
Contaminants
Where the contaminants go
A general process for waste hydrocarbons that carry halides, sulfur and organic nitrogen.
Halides (Cl, Br, F)
Converted to HCl, HBr and HF in the reactor and captured on the sorbent quench inside the skid.
Sulfur
Leaves the reactor mainly as H₂S with some COS. COS is hydrolyzed and H₂S removed in a conventional sulfur step sized to the feed.
Organic nitrogen
Mostly ends up as N₂. The small share of NH₃ and HCN is picked up in the condensate and treated in a sour water stripper.

Pilot program
The 2026 pilot campaign included diesel, mixed chemical waste, an aromatic and oxygenate mix and an industrial heavy aromatic solvent blend. The syngas had no measurable soot, with C₂H₂ below 50 ppm and C₆+ below 170 ppm. Data is available under NDA.
Suitability
Sites with recurring organic waste or off-gas streams that currently go to off-site disposal, and a use for syngas or power.
Every case is unique
Send us your stream.
Share the flow rate, composition and SDS for each waste stream. RegenSyn Energy screens it against the HTR feed envelope and comes back with a screening result and, where useful, a blend proposal. An NDA can be put in place first.
A feasibility study or pilot test is available on request.