Technology
A non-catalytic reactor for
contaminated organic waste
The Hydrogen Torch Reformer turns contaminated organic waste into syngas using heat and a controlled amount of oxygen instead of a catalyst. It ships as one modular skid with a sorbent halogen quench on the back end.
Modularity
Modular by design
The skid principle
One HTR skid, reactor plus quench, is the building block in every project. What changes is what goes before and after it, not the skid itself.
- Each skid treats up to 50,000 gallons per day of liquids, wastewater and liquid hydrocarbons combined
- The same design for every feed class
- Built and tested in the shop as one unit
- Quick to pilot on a customer’s actual waste
- Scale by adding skids

Pilot program
Corpus Christi pilot, 2026
A 6-inch HTR was run at the Corpus Christi pilot facility in 2026, at atmospheric pressure and pressurized. Feeds included diesel, an industrial heavy aromatic solvent blend, an aromatic and oxygenate mix, mixed chemical waste, propane, natural gas and eight PFAS-laden wastewaters.
The syngas from diesel to heavy aromatic feeds had no measurable soot, with C₂H₂ below 50 ppm and C₆+ below 170 ppm. Feed and product streams were analyzed by a third-party laboratory. Results demonstrate conversion to syngas. Detailed results are unpublished and available under NDA.

Technologies
Core technologies
1
The Hydrogen Torch Reformer
A non-catalytic, oxygen-lean reactor. A hydrocarbon, hydrogen and oxygen torch creates a reaction zone at 2,500 to 5,000 °F (1,370 to 2,760 °C); the bulk gas temperature is 2,100 to 3,600 °F (1,150 to 2,000 °C). Partial oxidation of the feed releases the heat. Steam and CO₂ reforming then raise the hydrogen and CO yield, and the oxygen-to-carbon ratio sets both temperature and gas composition. Waste streams can supply the carbon, the water, or both.
Summary
It runs hot enough to break organic molecules down to hydrogen and carbon monoxide. With no catalyst, contaminated feeds do not poison it.
2
The sorbent halogen quench
The hot gas from the reactor is cooled quickly. That freezes its composition and moves it through the 390 to 840 °F range, where unwanted recombination can occur, in as short a time as possible. Chlorine and fluorine, now in the form of HCl and HF, are captured on sorbent inside the skid.
Summary
It cools the gas rapidly and captures chlorine and fluorine on a solid sorbent inside the skid.
3
Process configuration
Around the skid, the pre-treatment (receiving, filtration, blending, concentration, pyrolysis for solids) and the downstream steps (sulfur removal, gas engine or turbine for power, fuel gas, methanol synthesis) are designed per project. All of it connects to fixed interfaces on the skid.
Summary
The skid stays the same. What comes before and after it is designed around the waste and the desired products.
Engineering basis
Selected HTR reactions
Above about 2,100 °F the reforming reactions run close to equilibrium within the reactor’s residence time. The gas that comes out is then set by temperature, pressure and the balance of carbon, hydrogen and oxygen, not by the exact molecules that went in. That is why one reactor can take very different waste. Pilot feeds ran from natural gas to a heavy aromatic solvent.
| Reaction | Stoichiometry (methane shown) | ΔH°, kJ/mol | Role |
|---|---|---|---|
| Partial oxidation | CH₄ + ½O₂ → CO + 2H₂ | −36 | Main syngas route |
| Combustion | CH₄ + 2O₂ → CO₂ + 2H₂O | −802 | Supplies heat, kept to a minimum |
| Steam reforming | CH₄ + H₂O → CO + 3H₂ | +206 | Uses the water in the waste |
| CO₂ reforming | CH₄ + CO₂ → 2CO + 2H₂ | +247 | Recycles CO₂ into CO |
| Water-gas shift | CO + H₂O ⇌ CO₂ + H₂ | −41 | Sets the H₂:CO ratio |
| Soot gasification | C + H₂O → CO + H₂ | +131 | Keeps carbon from building up |
Syngas from typical feeds
Process model results for an outlet temperature of 1,150 °C (2,100 °F) at 450 psig, with water moderation from H₂O/C 0.5 to 1.2. These are model results, not pilot data.
| Feed | H/C (atomic) | H₂/CO | O₂/C (mol/mol) | lb O₂ per lb feed | Feed carbon to CO, % |
|---|---|---|---|---|---|
| Methane (fuel or flare gas) | 4.0 | 2.00 to 2.03 | 0.73 to 0.86 | 1.46 to 1.72 | 75 to 84 |
| Propane (LPG, light ends) | 2.7 | 1.34 to 1.37 | 0.60 to 0.73 | 1.31 to 1.59 | 79 to 91 |
| C₁₂H₂₃ (diesel range, slop oil) | 1.9 | 0.97 to 1.00 | 0.56 to 0.68 | 1.28 to 1.57 | 80 to 94 |
| Benzene (aromatic solvent, wetter case only) | 1.0 | 0.55 | 0.58 | 1.42 | 87 |
H₂/CO follows the feed
H₂/CO comes out at about half the feed’s H/C ratio, almost independent of O₂/C.
Oxygen demand is predictable
Oil and gas range feeds need about 1.3 to 1.7 lb O₂ per lb of feed, before any credit for preheat, steam moderation and heat recovery.
Aromatics use more water
Benzene already reaches higher adiabatic temperatures, so aromatic feeds take more wastewater per lb of feed as temperature moderator.
Where the contaminants go
Feed contaminants in, defined species out
| In the feed | Leaves the reactor as | Handled by | End point |
|---|---|---|---|
| Organic compounds | CO, H₂, CO₂, H₂O | Product syngas | Syngas product |
| Chlorine | HCl | Sorbent quench, on the skid | Chloride solids |
| Fluorine, including PFAS | HF | Sorbent quench, on the skid | Fluoride solids |
| Sulfur | H₂S, COS | Downstream sulfur removal | Recovered sulfur |
| Nitrogen | Mostly N₂, some NH₃ and HCN | Downstream gas and water treatment | N₂ in the syngas; NH₃ and HCN treated |
| Sodium | Sodium salts | Quench water | Condensate and solids blowdown |
| Salts and metals | Solids, liquids or gases | Evaluated on a case by case basis | Case by case |
Skid specifications
The HTR skid
| Skid scope | Feed injection, HTR reactor plus sorbent halogen quench |
| Reaction zone | 2,500 to 5,000 °F (1,370 to 2,760 °C) |
| Reactor outlet temperature | 2,100 to 3,600 °F (1,150 to 2,000 °C) |
| Catalyst | None |
| Feeds | Liquids, gases and vapors; solids through upstream pyrolysis |
| Capacity per skid | 50,000 gallons per day of liquids (wastewater and liquid hydrocarbons combined), about 1,190 bbl/day |
| Project throughput | 10,000 to 150,000 gallons per day of wastewater and waste hydrocarbon combined |
| Oxidant | Oxygen or enriched air |
| Operating pressure | Pressurized |
| Halogen sorbent | Specified per project |
| Footprint | Specified per project |
Every case is unique
Evaluate the HTR on a specific stream.
Share a description of the waste stream and RegenSyn Energy will give a first view of whether it fits the HTR and what it could produce. An NDA can be put in place first.
A feasibility study or pilot test is available on request.