Technology

A non-catalytic reactor for
contaminated organic waste

The Hydrogen Torch Reformer turns contaminated organic waste into syngas using heat and a controlled amount of oxygen instead of a catalyst. It ships as one modular skid with a sorbent halogen quench on the back end.

Modularity

Modular by design

The skid principle

One HTR skid, reactor plus quench, is the building block in every project. What changes is what goes before and after it, not the skid itself.

  • Each skid treats up to 50,000 gallons per day of liquids, wastewater and liquid hydrocarbons combined
  • The same design for every feed class
  • Built and tested in the shop as one unit
  • Quick to pilot on a customer’s actual waste
  • Scale by adding skids
The HTR reactor at the Corpus Christi pilot facility, 2026

Pilot program

Corpus Christi pilot, 2026

A 6-inch HTR was run at the Corpus Christi pilot facility in 2026, at atmospheric pressure and pressurized. Feeds included diesel, an industrial heavy aromatic solvent blend, an aromatic and oxygenate mix, mixed chemical waste, propane, natural gas and eight PFAS-laden wastewaters.

The syngas from diesel to heavy aromatic feeds had no measurable soot, with C₂H₂ below 50 ppm and C₆+ below 170 ppm. Feed and product streams were analyzed by a third-party laboratory. Results demonstrate conversion to syngas. Detailed results are unpublished and available under NDA.

Close-up of the HTR torch ring with natural gas and oxygen feed lines, Corpus Christi pilot, 2026

Technologies

Core technologies

1

The Hydrogen Torch Reformer

A non-catalytic, oxygen-lean reactor. A hydrocarbon, hydrogen and oxygen torch creates a reaction zone at 2,500 to 5,000 °F (1,370 to 2,760 °C); the bulk gas temperature is 2,100 to 3,600 °F (1,150 to 2,000 °C). Partial oxidation of the feed releases the heat. Steam and CO₂ reforming then raise the hydrogen and CO yield, and the oxygen-to-carbon ratio sets both temperature and gas composition. Waste streams can supply the carbon, the water, or both.

Summary

It runs hot enough to break organic molecules down to hydrogen and carbon monoxide. With no catalyst, contaminated feeds do not poison it.

2

The sorbent halogen quench

The hot gas from the reactor is cooled quickly. That freezes its composition and moves it through the 390 to 840 °F range, where unwanted recombination can occur, in as short a time as possible. Chlorine and fluorine, now in the form of HCl and HF, are captured on sorbent inside the skid.

Summary

It cools the gas rapidly and captures chlorine and fluorine on a solid sorbent inside the skid.

3

Process configuration

Around the skid, the pre-treatment (receiving, filtration, blending, concentration, pyrolysis for solids) and the downstream steps (sulfur removal, gas engine or turbine for power, fuel gas, methanol synthesis) are designed per project. All of it connects to fixed interfaces on the skid.

Summary

The skid stays the same. What comes before and after it is designed around the waste and the desired products.

Engineering basis

Selected HTR reactions

Above about 2,100 °F the reforming reactions run close to equilibrium within the reactor’s residence time. The gas that comes out is then set by temperature, pressure and the balance of carbon, hydrogen and oxygen, not by the exact molecules that went in. That is why one reactor can take very different waste. Pilot feeds ran from natural gas to a heavy aromatic solvent.

ReactionStoichiometry (methane shown)ΔH°, kJ/molRole
Partial oxidationCH₄ + ½O₂ → CO + 2H₂−36Main syngas route
CombustionCH₄ + 2O₂ → CO₂ + 2H₂O−802Supplies heat, kept to a minimum
Steam reformingCH₄ + H₂O → CO + 3H₂+206Uses the water in the waste
CO₂ reformingCH₄ + CO₂ → 2CO + 2H₂+247Recycles CO₂ into CO
Water-gas shiftCO + H₂O ⇌ CO₂ + H₂−41Sets the H₂:CO ratio
Soot gasificationC + H₂O → CO + H₂+131Keeps carbon from building up

Syngas from typical feeds

Process model results for an outlet temperature of 1,150 °C (2,100 °F) at 450 psig, with water moderation from H₂O/C 0.5 to 1.2. These are model results, not pilot data.

FeedH/C (atomic)H₂/COO₂/C (mol/mol)lb O₂ per lb feedFeed carbon to CO, %
Methane (fuel or flare gas)4.02.00 to 2.030.73 to 0.861.46 to 1.7275 to 84
Propane (LPG, light ends)2.71.34 to 1.370.60 to 0.731.31 to 1.5979 to 91
C₁₂H₂₃ (diesel range, slop oil)1.90.97 to 1.000.56 to 0.681.28 to 1.5780 to 94
Benzene (aromatic solvent, wetter case only)1.00.550.581.4287

H₂/CO follows the feed

H₂/CO comes out at about half the feed’s H/C ratio, almost independent of O₂/C.

Oxygen demand is predictable

Oil and gas range feeds need about 1.3 to 1.7 lb O₂ per lb of feed, before any credit for preheat, steam moderation and heat recovery.

Aromatics use more water

Benzene already reaches higher adiabatic temperatures, so aromatic feeds take more wastewater per lb of feed as temperature moderator.

Where the contaminants go

Feed contaminants in, defined species out

In the feedLeaves the reactor asHandled byEnd point
Organic compoundsCO, H₂, CO₂, H₂OProduct syngasSyngas product
ChlorineHClSorbent quench, on the skidChloride solids
Fluorine, including PFASHFSorbent quench, on the skidFluoride solids
SulfurH₂S, COSDownstream sulfur removalRecovered sulfur
NitrogenMostly N₂, some NH₃ and HCNDownstream gas and water treatmentN₂ in the syngas; NH₃ and HCN treated
SodiumSodium saltsQuench waterCondensate and solids blowdown
Salts and metalsSolids, liquids or gasesEvaluated on a case by case basisCase by case

Skid specifications

The HTR skid

Skid scopeFeed injection, HTR reactor plus sorbent halogen quench
Reaction zone2,500 to 5,000 °F (1,370 to 2,760 °C)
Reactor outlet temperature2,100 to 3,600 °F (1,150 to 2,000 °C)
CatalystNone
FeedsLiquids, gases and vapors; solids through upstream pyrolysis
Capacity per skid50,000 gallons per day of liquids (wastewater and liquid hydrocarbons combined), about 1,190 bbl/day
Project throughput10,000 to 150,000 gallons per day of wastewater and waste hydrocarbon combined
OxidantOxygen or enriched air
Operating pressurePressurized
Halogen sorbentSpecified per project
FootprintSpecified per project

Every case is unique

Evaluate the HTR on a specific stream.

Share a description of the waste stream and RegenSyn Energy will give a first view of whether it fits the HTR and what it could produce. An NDA can be put in place first.

A feasibility study or pilot test is available on request.